Calculate No of Street Light Poles _ Electrical Notes & Articles

STEEL ROUND POLES - LSI Industries

kornegayengineering wp content uploads 2011 05 Special Research Topic Report on Current Practice in Utility Distribution Poles and Light Poles Adam Crosby Date 5 05 11 1 0 Objective The objective of this report is to present a summary of the current practice of the structural design of

Related PDF

Structual Design of Utility Distribution Poles and Light Poles

kornegayengineering wp content uploads 2011 05 Special Research Topic Report on Current Practice in Utility Distribution Poles and Light Poles Adam Crosby Date 5 05 11 1 0 Objective The objective of this report is to present a summary of the current practice of the structural design of utility distribution poles and light poles, including the poles and foundations This summary includes
PDF

Street Light Design Manual - Oakland, California

2 oaklandnet oakca1 groups pwa documents policy 3 4 Calculate uniformity ratio for each street in project 3 4 1 Uniformity Ratio –The ratio of the Average Maintained Illuminance level to the Minimum Maintained Illuminance level 3 5 Location of street light(s) shall match street light layout plan 4 SiService ElEnclosure 4 1
PDF

Light Poles: A Guide to their selection, installation and

cooperindustries acf090398 poles white paper pdf Light poles are structures designed to support single or multiple luminaire configurations First and foremost a light pole is an engineered structure—sufficiently strong to withstand the physical forces of the application, capable of providing a long, relatively maintenance free service life and pleasing in appearance
PDF

SPECIAL SPECIFICATIONS FOR THE CONSTRUCTION OF STREET

bsl lacity downloads business Bluebook2009R3 pdf contractors No deviations from the “Special Specifications, “Standard Specification”, or “Standard Plans” are authorized for street lighting construction within the City of Los Angeles without prior approval from the Bureau of Street Lighting If there is a conflict between documents, precedence of documents
PDF

ROAD LIGHTING CALCULATIONS - 51ballastcn

51ballast cn tec gf 8 pdf ROAD LIGHTING CALCULATIONS CIE 140 2000 Rev No Date Revision Notes 1 July 2006 Page 19 Fig 13 Dual carriageway Upper shaded area, as a calculation area in the opposite driving direction, where in the lanes no observers are positioned, has been removed 2 December 2006 ISBN Number on the cover pages has been corrected
PDF

A STUDY OF SOLAR STREET LIGHT AND OPTIMIZATION FOR SPACING IN


PDF

Streetlights for Local Roads - lrcrpiedu

lrc rpi edu programs NLPIP PDF VIEW SR photometry, manufacturer supplied photometric data, higher light output street lights, higher mounting heights, wider roads, and volume discount pricing Using a GE Lighting 100 W HPS streetlight as the tested base case, NLPIP found that † The tested LED streetlights required 3 to 92 (average 40 ) more poles
PDF

STEEL ROUND POLES - LSI Industries


PDF

PDF ESTIMATING EARTHWORKcivil utm my shaifulamri files 2012 09 Basic Eathwork Estimate pdf PDF Chapter 3 Earthwork FDOT fdot gov roadway ppmmanual 2017 Volume1 Chap03 pdf PDF 6 Measurement and Earthwork Calculations IN gov in gov

  1. earthwork calculation spreadsheet
  2. how to calculate cut and fill by hand
  3. earthwork calculation software
  4. earthwork estimation calculation for road
  5. earth work calculation by simpson's rule
  6. road work calculation quantities
  7. earth work calculation formula pdf
  8. earthwork in road construction pdf

Calculating Mortar Data

Guide for Modeling and Calculating Shrinkage

the eye eu public Strategic Intelligence Network Instruments for Calculating Mortar Firing Data PREFACE AIM 1 This publication has been issued for personnel who use and teach the use of the plotter and the Mortar Fire Data Calculator (MFDC) SCOPE 2 The purpose of this publication is

Calculation Based on DIN 55474

Packaging Instructions

PDF Calculation Based On Din 55474 Tropack Com home Homeapi aerofit dk calculation based on din 55474 tropack com pdf PDF Technical Guideline Handling , Packaging and Storage GSI IndiCo indico gsi de event 1420 material 0 36

Calculation Chemical Storage (Steel)

Chapter 5: CHEMICAL STORAGE - Lehman College

powderbulk enews story pdf pbe 20120321 Welded Steel Tanks for Oil Storage, ANSI AWWA D100 11 AWWA Standard for Welded Carbon Steel Tanks for Water Storage,and Underwriters Laboratories (UL) 142 Stan dard for Steel Aboveground Tanks for Flammable and Com bustible

Calculation for Service Platform & Pump Shelter Structure

CODE OF PRACTICE ON SURFACE WATER DRAINAGE

fema gov media library data 20130726 1506 Sample Design Calculations This appendix presents design examples of the retrofitting techniques for elevation, dry floodproofing, wet floodproofing, and construction of a floodwall in a residential setting Examples C1 through C5 are a set of examples that illustrate the

CALCULATION OF CRANKSHAFTS diesel engine.pdf

Diesel Engine Combustion - MIT

rules dnvgl docs pdf DNV cn 2002 01 CN41 3 pdf CLASSIFICATION NOTES No 41 3 DET NORSKE VERITAS Veritasveien 1, N 1322 Hłvik, Norway Tel +47 67 57 99 00 Fax +47 67 57 99 11 CALCULATION OF CRANKSHAFTS FOR DIESEL

Calculation of Displacement, LWT and DWT

DESIGN CONCEPT METHODOLOGY DEVELOPMENT FOR LPG CARRIER

foreship files fs naterms pdf Displacement of a Panamax (approximately 90,000 GT) cruise vessel is e g ca 47,000 t Displacement Force (symbol') is Displacement Weight x g (g=9 81 m s2), and is the same as buoyancy Displacement volume ( ) The volume

Calculation of Invert Levels

Site sewer construction guide - United Utilities

Design 1) Indicate the invert elevation on profile for each pipe entering and leaving the manhole at the Solve for (b), using this formula b = (c2 − a2)1 2 Then  PROPOSED CONSTRUCTED WETLANDS – DESIGN CALCULATIONS – REV 1 0 Remarks

  1. CALCULATION SHEET
  2. Pit and Pipe Invert Levels
  3. Self-cleansing flow conditions for inverted siphons
  4. using this formula
  5. calculated by subtracting the invert level from the cover
  6. pipe invert levels shown on pit schedules and drainage longitudinal
  7. Further guidance on the estimation of the flows and loads
  8. 675mm and invert levels exceeding 6m below ground level
  9. level 1
  10. 2Difference of 9 ft3 from calculated value from rounding

Calculation of Pressure Traverse Using Beggs and Brill

Evaluation of Models to Predict Liquid Loading in Gas wells - NTNU

PDF Beggs and Brill method NMT edu nmt edu ~petro faculty Kelly BaBr pdf PDF a condensation model for calculating pressure gradients in sciencedirect science article pii md5 pid=1 PDF Pressure Gradient Prediction

  1. beggs and brill pressure drop calculation xls
  2. multiphase flow correlations
  3. pressure traverse curves pdf
  4. beggs and brill z factor correlation
Home back Next

te No of Street Light Poles _ Electrical Notes & Articles

Description

Calculate No of Street Light Poles | Electrical Notes & Articles

com/2014/05/04/calculate-no-of-street

Electrical Notes & Articles Sharing Abstracts,Notes on various Electrical Engineering Topics

MAY 4, 2014 24 COMMENTS (HTTPS://ELECTRICALNOTES

WORDPRESS

COM/2014/05/04/CALCULATE‐NO‐OF‐STREET‐ LIGHT‐POLES/#COMMENTS)

Luminaries are properly selected and mounted on a location most feasible and effective with minimum cost

 For a 230 volts system, a voltage drop of 5% is allowed although in extreme cases 15% voltage drop is sometimes tolerated

jpg) Street illumination level in Lux (E)=(Al x (cu x mf)) / (w x d) E = The illumination in Lux w = Width of the roadway d = Distance between luminaries cu = Coefficient of utilization

 Which is dependent on the type of fixture, mounting height, width of roadway and the length of mast arm of outreach

? Al = Average lumens, Al = (E x w x d) / Cu x mf The typical value of Al is 20500 lumens for 400 watts 11500 lumens for 250 watts 5400 lumens for 125 watts The value of Al varies depending upon the type of lamp specified

mf : It is the maintenance factor (Normally 0

8 to 0

Calculate Lamp Lumen for street Light Pole having Road width of 7 meter, distance between two Pole is 50 meter, Maintenance factor is 0

Solution: From Above table Recommended of illumination (E) in Lux is 6

 meter

Average Lumen of Lamp (Al)=(E x w x d) / Cu x mf Al=(6

9)= 8662

83 lumen

 Therefore, a 250 watts lamp is acceptable

Let’s Computing for the actual illumination E for 250 Watt Lamp

Calculate No of Street Light Poles | Electrical Notes & Articles

com/2014/05/04/calculate-no-of-street

Illumination (E)=(Al x (cu x mf)) / (w x d) E= (11500×0

Conclusion: Actual illumination (E) for 250 Watt is 8

Hence 250 watt gives adequately lighting

Calculate Space between Two Pole of Street Light having Fixture Watt is 250W , Lamp output of the Lamp (LL) is 33200 lumens ,

Required Lux Level (E) is 5 lux , Width of the road (W) = 11

5 M),Height of the pole (H) = 26

8 ,Luminaries dirt Depreciation Factor (LDD) = 0

Luminaries Spacing (S) = 75 feet (23 Meters)

The allowed illumination time in hours T = k

Where: k = extension factor t = permissible time in hours at 1000 lux, unfiltered daylight E = luminance (lx)

Extension Factor Lamp

Extension Factor

Incandescent lamps,

7 to 3

Halogen reflector lamps

5 to 3

Halogen capsules

5 to 3

High‐pressure metal‐halide

1 to 2

High‐pressure sodium lamps

Fluorescent lamps

9 to 2

Example: In sunlight (100000 lux) and extension factor 1: The permissible illumination time (T) =1 x 70 x 1000/100 000 = 0

7 hour

In halogen light (200 lux) and extension factor 2

3 x 70 x 1000/200 = 805 hours

In UV‐filtered halogen light (200 lux) and extension factor 3

5 x 70 x 1000/200 = 1225 hours

Once luminaries spacing has been decided It is necessary to check the uniformity of light distribution and compare this value to the selected lighting Uniformity Ratio ( UR) = Eav /Emin

Calculate No of Street Light Poles | Electrical Notes & Articles

com/2014/05/04/calculate-no-of-street

Eav= average maintained horizontal luminance Emin = maintained horizontal luminance at the point of minimum illumination on the pavement

At a simplistic level, the cost of running a light is directly related to the wattage of the globe plus any associated ballast or transformer

 The higher the wattage, the higher the running cost and it is a straightforward calculation to work out the running cost of lamp over its lifetime: Running cost = cost of electricity in $/kWh x wattage of lamp x lifetime in hours

The Average Lux Level of Street Light is measured by 9 point method

 Make two equal quadrants between two Street light poles

on the lane of light poles( one side pole to road)

We have 3 points P1,P2 and P3 under the light pole then P4 & P7 are points opposite pole 1 or Point P3 same is applicable for P6 and P9 for Pole 2

The average lux = [(P1+P3+P7+P9)/16]+[(P2+P6+P8+P4)/8]+[P5/4]

You May Like

Here's How Destiny's Child Maybe Affected The Name Destiny,

com Huffington Post HuffingtonPost

com (AOL) The Huffington Post News Team The FILED UNDER UNCATEGORIZED About Jignesh

Parmar Jignesh Parmar has completed M

Tech (Power System Control), B

E(Electrical) from Gujarat University

 He has more than 13 years experience in Power Transmission‐Power Distribution‐Electrical energy theft detection‐Electrical Maintenance‐Electrical Projects(Planning‐Designing‐coordination‐Execution)

 He is Presently associate with one of the leading business group as a Deputy Manager at Ahmedabad,India

 He is Freelancer Programmer of Advance Excel and design useful Excel Sheets of Electrical Engineering as per IS,NEC,IEC,IEEE codes

 He is technical Author for ʺElectrical Mirrorʺ and ʺElectrical Indiaʺ Magazines

 He is Technical Blogger and Familiar with English, Hindi, Gujarati, French languages

 He wants to Share his experience & knowledge and help technical enthusiasts to find suitable solutions and updating themselves on various Engineering Topics

 thanks

Calculate No of Street Light Poles | Electrical Notes & Articles

com/2014/05/04/calculate-no-of-street

goutam says: May 4, 2014 at 12:00 pm Plz dehumidifier calculation sheet make and sent me

Reply Jignesh

Parmar says: May 4, 2014 at 4:13 pm Yes sir, But what is Dehumidifier 

? Reply Atta Khan says: May 5, 2014 at 6:34 am seen thanks Ak Reply Ashish Lotake says: May 8, 2014 at 6:39 am Thanks for forwarded notes

 also forwarded the 33kv line deatils like conductor size,materials list and etc……

Reply darwin says: May 9, 2014 at 3:49 am sir i couldn’t see the table of Recommended Illuminations like what you have said in your example

 May you send it to me

Reply darwin says: May 9, 2014 at 3:53 am Example on Calculate Lamp Watt for Street light Pole sir

Reply Jignesh

Parmar says: May 10, 2014 at 5:06 pm Dear Darwin,

It is already explain in Post… amrendra kumar says: May 13, 2014 at 11:59 am very interesting…

))) Reply uday raj maurya says: July 29, 2014 at 7:48 am Required all power & control cable current calculation chart

Reply sahal vhora says: August 20, 2015 at 12:54 pm same here Reply mohamed says: October 14, 2014 at 12:25 pm please i want to know more about 9‐points method and other methods like 12‐points method and more Reply levanluong says: October 18, 2014 at 1:33 am very interesting

 thanks sr

! Reply Rushil says: November 2, 2014 at 3:49 pm i am a student and i do not understand the need for an outreach in a lamp post can you explain Reply pramod kumar chaturvedi says: December 26, 2014 at 9:57 am Required out door street light lux calculations chart (1) pole mounting height 7

Calculate No of Street Light Poles | Electrical Notes & Articles

com/2014/05/04/calculate-no-of-street

mtr (4) boom angle 1o dig (5) arrangement double row with offset (6) luminaire wattage 172 w (7) luminous flux (lamps) 17000 lm (8) Road width 7 mtr (9) Required Lux Level mim 20 lux (10) light loss factor 0

CAN U PLEASE GUIDE ME TO CALCULATE LUX LEVEL OF A FOOT BALL STADIUM Reply eric says: May 13, 2015 at 4:26 pm good day sir i have a problem to calculate the luminous flux of a lamp wattage of 250watts,height of pole 7

5 please can u help me out Reply SAJIN says: May 25, 2015 at 6:59 am Dear Sir,\ Thanks for the details and is very helpful, My doubt is why this calculation vales not related to pole height

? How we can determine pole height for a out door lighting project

? How we can determine wattage for a fixture which is placed at high level area

Please reply Reply Kailas Watekar says: June 2, 2015 at 3:06 pm To find the distance between two street light pole of 9 meter height having fitting of 250 watt high pressure mercury vapour Reply Varad Enterprises says: July 18, 2015 at 9:29 pm Hello Jignesh Sir,

Can you please guide me how to calculate the voltage drop in designing the street lighting

 Want to determine the size of the cable to be used for the highway road where 120W LED Street lighting is to be used

 Span between the pole is assumed to be 20‐25 m and the lighting poles are in the middle of the 100 m road Reply Vineeth Kumar C G says: July 28, 2015 at 9:27 am simple but u didn’t considered pole mounting height

? what is the standard street light height

? Reply sansereyvathna says: October 16, 2015 at 8:17 am where is table Recommended of illumination

? I can’t see it

Reply sandeep ji says: December 30, 2015 at 2:18 pm dear sir / madam this is good but practical data is not mach , utilization and multiplication factor how to decide , any one can give me right solution for street light pole , wattage , lux any formula please explain me ,

sandeep kumar m:‐09914421455 [email protected] Reply getnet says: February 3, 2016 at 11:27 am pleace notify standards for home installation via my e mail